3.
Revisions
to
the
Text
of
the
Draft
EIR
Page
4.J-26
OSEC-404
[See
page
5-360
for
the
original
comment],
SFPUC-4
[See
page
5-
77
for
the
original
comment]
REVISE
the
first
full
paragraph
to
read:
Conclusion
with
Mitigation:
With
implementation
of
Mitigation
Measures
4.J-2a,
and
4.J-2b,
and
4.J-2c,
groundborne
vibration
impacts
on
multi-family
housing
under
the
DSP
and
DSP-V
scenarios,
and
on
the
Roundhouse
and
underground
utilities
and
pipelines.
for
Project
Site
development
would
be
less
than
significant.
Page
4.J-31
UPC
2-13
[See
page
5-532
for
the
original
comment]
REVISE
Mitigation
Measure
4.J-3a
as
follows.
Mitigation
Measure
4.J-3a:
All
development
within
the
Baylands
Project
Site
shall
incorporate
the
following
design
features
into
the
final
site
plans
prior
to
issuance
of
a
building
permit:
Building
equipment
(e.g.,
heating,
ventilation,
and
air
conditioning
units)
shall
be
located
away
from
nearby
residences,
on
building
rooftops,
or
adequately
shielded
within
an
enclosure
that
effectively
blocks
the
line
of
sight
of
the
source
from
receivers
in
order
to
meet
a
performance
standard
of
5
dBA
over
existing
ambient
noise
levels
(generally
perceptible
increase
to
most
persons)
for
this
source
which
would
potentially
operate
more
than
20
minutes
in
a
given
hour.
Formal
truck
delivery
areas
(e.g.
loading
bays)
shall
be
located
at
least
100
feet
from
residences
to
maintain
noise
levels
of
less
than
5
dBA
over
existing
monitored
levels,
except
within
mixed-use
buildings
containing
both
residential
and
commercial
uses.
Truck
delivery
bays
and
waste
collection
areas
shall
be
located
so
that
they
are
blocked
by
Project
Site
development
buildings
or
designed
with
noise
reduction
barriers
to
reduce
noise
impacts
on
residences
or
other
sensitive
receptors.
Where
truck
delivery
bays
are
provided
within
mixed-use
buildings
containing
both
residential
and
commercial
uses,
they
shall
be
located
and
designed
so
as
to
minimize
the
effects
of
noise
from
loading
activities
on
residential
uses
within
the
building.
Page
4.J-31
OSEC-306
[See
page
5-350
for
the
original
comment]
REVISE
Mitigation
Measure
4.J-3b
based
on
recommendations
of
the
Renewable
Energy
Research
Laboratory
(RERL,
2004)
as
follows:
Mitigation
Measure
4.J-3b:
Small
wind
turbines
shall
be
sited
a
minimum
of
50
feet
from
the
property
line
of
noise
sensitive
land
uses
(e.g.,
residential,
schools,
religious
institutions).
,
and
uUtility
scale
wind
turbines
shall
be
csited
a
minimum
of
100
feet
from
the
property
line
of
noise
sensitive
land
uses
and
separated
from
one
another
by
a
distance
no
less
than
a
minimum
of
two
times
the
rotor
diameter
of
the
larger
turbine.
Brisbane
Baylands
Final
EIR
3-103
May
2015
Previous Next