2.
Response
to
Comments
2.9
Individual
Responses
to
Comments
from
Organizations
Recology
facility
will
be
designed
to
“back-up
to
the
Beatty
Subarea,
locating
less
sensitive
site
functions
such
as
parking,
service
access,
and
storage
at
the
rear
of
the
site
adjacent
to
the
Beatty
subarea.”
The
residential
uses
proposed
in
the
DSP
and
DSP-V
scenarios
are
separated
from
the
Recology
facility
by
a
proposed
strip
of
retail
uses
between
Recology
and
the
Caltrain
right-of-way
and
the
Caltrain
right-of-way
itself,
and
are
located
further
from
Recology
than
residential
uses
to
the
north
of
Recology
in
San
Francisco.
Recology-27
[See page
5-493 for the original comment]
The
specific
responses
to
each
of
the
assertions
in
this
comment
are
addressed
in
the
following
10
responses.
The
analysis
of
GHG
emissions
contained
in
the
Draft
EIR
relative
to
the
CPP-V
development
scenario
inclusive
of
the
Recology
expansion
project
considered
GHG
reductions
from
photovoltaics
and
waste-stream-based
biogas
in
the
category
entitled
Recology
Renewable
Energy
Implementation
in
Tables
4.F-2
and
4.F-3
.
The
Final
EIR
includes
an
updated
estimation
of
Project
Site
development-
related
GHG
emissions
based
on
the
latest
version
of
the
CalEEMod
model,
which
was
released
in
October
2013
subsequent
to
the
release
of
the
Draft
EIR.
The
updated
emission
inventory
is
provided
as
a
text
revision
in
Section
3.4,
Greenhouse
Gas
Emissions
in
Volume
III
of
the
Final
EIR.
GHG
emissions
under
the
CPP-V
scenario
are
now
estimated
at
3.2
metric
tons
per
year
per
service
population,
and
would
be
below
the
significance
threshold.
Consequently,
the
CPP-V
scenario
is
identified
in
the
Final
EIR
as
having
a
less
than
significant
impact
with
regard
to
GHG
emissions.
Recology-28
[See page
5-494 for the original comment]
The
Final
EIR
includes
an
updated
estimation
of
Project
Site
development-related
GHG
emissions
based
on
the
latest
version
of
the
CalEEMod
model,
which
was
released
in
October
2013
subsequent
to
the
release
of
the
Draft
EIR.
This
updated
estimation
of
energy
use
considers
the
Recology
expansion
to
have
a
net
zero
power
demand.
Reductions
in
GHG
from
photovoltaics
and
waste-stream-based
biogas
are
considered
separately
in
the
category
entitled
Recology
Renewable
Energy
Implementation
in
Table
4.F-2
and
Table
4.F-3
.
[See page
5-494 for the original comment]
The
Final
EIR
includes
an
updated
estimation
of
Project
Site
development-related
GHG
emissions.
This
updated
emissions
estimation
now
reflects
a
73
metric
ton
reduction
in
GHG
from
the
CPP-V
scenario
as
a
result
of
offset
natural
gas
use
resulting
from
the
integrated
renewable
energy
portfolio.
Comment
Recology-29
requests
that
the
Baylands
EIR
consider
the
reduction
in
emissions
from
other
existing
Recology
sites
that
would
be
consolidated
at
the
proposed
expanded
facility
under
the
CPP-V
scenario.
While
there
would
be
a
Recology-29
Brisbane
Baylands
Final
EIR
2.9.7-6
May
2015
Previous Next