OSEC
Open
Space
&
Ecology
CEQA
Comments
on
Brisbane
Baylands
Draft
EIR
-
2013
Page4.H-22
Development
of
the
area
will
increase
urban
pollutants.
Materials
that
are
used
to
construct
buildings
should
be
considered
to
limit
the
impact
of
nonpoint
source
pollutants
during
the
planning
process.
In
the
DEIR
have
the
creation
of
the
materials
been
taken
into
account
for
impacts
area
wide,
such
as
lumber
use
and
deforestation?
Has
the
impacts
of
the
materials
and
the
source
of
the
materials
been
taken
into
account?
Page
4-H-25
Impact
4.H-2
should
be
significant
since
there
will
be
no
new
infiltration
of
groundwater.
Existing
groundwater
will
not
be
recharged,
thus
causing
subsidence.
There
should
be
mitigation
measures
for
recharge.
Page4.H-25
Groundwater
recharge
In
discussion
of
Impact
4H-2
(p.
4H-25),
the
DEIR
says
the
amount
of
direct
groundwater
recharge
will
be
reduced,
but
will
have
a
less
than
significant
impact.
There
have
been
much-publicized
instances
of
subsidence
resulting
from
reduction
in
aquifer
volume
.
Could
a
reduction
in
the
amount
of
recharge
lead
to
subsidence
here?
In
the
discussion
following,
the
DEIR
says
that
"
...
even
if
groundwater
levels
were
to
be
reduced
(and
with
its
close
proximity
to
the
lagoon
and
Bay
there
may
be
a
negligible
effect)
....
"
This
seems
to
argue
for
infiltration
of
bay
water
into
the
Baylands,
which
is
very
likely,
but
in
other
parts
of
the
DEIR,
it
is
reported
that
there
is
no
such
infiltration
into
the
landfill.
Page4.H-25
There
are
two
paragraphs
on
this
page
discussing
possible
aquifer
depletion
resulting
from
the
prevention
of
water
infiltration
that
would
otherwise
recharge
the
aquifer.
Is
it
possible
that
aquifer
depletion
would
lead
to
ground
subsidence?
This
issue
is
not
considered
in
any
depth
and
its
treatment
on
this
page
is
not
only
brief,
but
apparently
contradictory.
Page4.H-29
Mitigation
measure
4.H-4a,b
and
c
should
use
a
100-year
storm
event
after
sea
level
rise
projections
due
to
global
warming,
including
high
tide.
Using
a
100-year
storm
event
will
ensure
proper
mitigation
of
statements
on
4.H-37.
The
mitigation
should
take
into
account
subsidence
for
non-supported
areas
of
the
site.
Mitigation
should
take
subsidence
into
account
after
the
completion
of
the
project.
Page4.H-29
Storm
drainage
system
improvements
Mitigation
Measure
4H-4a
and
4H-4b.
Prior
to
development
a
system
wide
drain
improvements
plan
should
be
approved
by
City
Council.
How
will
the
drainage
system
handle
everything
before,
during
and
after
construction?
Page4.H-29
4.H-4a
requires
that
the
floor
elevations
provide
a
minimum
of
I-foot
of
freeboard
above
the
100-year
storm
event.
The
DEIR
concludes
that
this
impact
is
not
significant.
A
cross
sectional
perspective
of
the
data
will
show
that
this
margin
of
error
is
insufficient
due
to
the
potential
of
subsidence
detailed
in
section
4.E
and
the
likelihood
of
sea
level
rise
detailed
in
this
section.
For
example
page
4.H-37
indicates
that
an
11.8"
rise
in
sea
level
would
shift
the
100-year
storm
surge-induced
flood
even
to
once
every
10
years.
The
chart
below
from
Climate
Central,
displays
projections
of
flooding;
which
shows
an
estimate
of
11
inch
sea
level
rise
in
S.F
Bay
by
2050.
A
secondary
concern
with
sea
level
rise
is
subsidence
of
certain
facilities
and
the
potential
for
contamination
and/or
loss
of
facilities.
Kinder
Morgan
is
a
petroleum
storage
and
transport
facility,
which
had
experienced
subsidence
over
time
as
1
mentioned
in
the
April
4
h,
2011
council
meeting
at
Brisbane
City
Hall.
Subsidence
in
combination
with
sea
level
rise
is
a
concern
and
mitigation
should
be
considered.
I
40
5-345