SJohnson
Appendix
4
Scenario
4
-
Direct
Measurement
of
Soil
Gas
Concentrations
Soil
Gas
Sampling
Loc
ations
-
No
Bioattenuation
Zone
Existing
Building
Future
Const
r
u
ctio
n
t
S'
Depth
of
Foundation
------------
~
-----
a
t
---------
~
--------
t
b
Description
of
Soil
Gas
Sample
Locations
a
-
beneath
or
adjacent
to
building
(soil
gas
sample
shall
be
collected
at
least
5'
deeper
than
the
bottom
of
the
building
foundation)
b
-
for
future
construction
scenarios
(soil
gas
sample
shall
be
collected
at
least
5'
below
the
ground
surface)
Soil
Gas
Sampling
Locations
-
with
Bioattenuation
Zone
Existing
Building
Future
Construction
0
2
~
4%
at
lower
end
of
zone
0
2
~
4%
at
lower
end
of
zone
Required
Characteristics
of
Bioattenuation
Zone
Required
data
includes:
petroleum
concentrations
in
soil
and
soil
gas,
and
oxygen
concentrations.
Measured
concentrations
of
soil
gases
must
be
less
than
the
s
creening
values
indicated
in
the
table
below
for
the
applicable
Soil
Gas
Screening
Levels
(ug/m
3
)
Notes:
·
in
order
to
use
the
screening
levels
with
the
bioattenuation
zone.
there
must
be:
1)
5
feet
of
soil
between
the
soil
vapor
measurement
and
the
building
(or
future
building).
2)
TPH
(TPHg
+
TPHd)
is
less
than
100
ppm
(measured
in
at
least
two
depths
within
the
5
foot
zone),
and
3)
oxygen
~
4%
measured
at
the
bottom
of
the
5
foot
bioattenuation
zone.
A
1000-fold
bioattenuation
of
petroleum
vapors
is
assumed
for
the
bioattenuation
zone.
For
the
no
bioattenuation
zone,
the
screening
criteria
are
the
same
as
the
California
Human
Health
Screening
Levels
(CHHSLs).