4.
Mitigation
Monitoring
and
Reporting
Program
Mitigation
Monitoring
and
Reporting
Matrix
(continued)
Significant
Impact
Being
Mitigated
Cultural
Resources
(cont.)
Roundhouse
are
available
at
the
Library
and
Collections
Department
of
the
California
State
Railroad
Museum
in
Sacramento.
These
original
plans
and
early
photographs
shall
be
used
when
preparing
the
rehabilitation
plan
for
this
building
to
ensure
that
rehabilitation
efforts
will
adequately
preserve
the
historic
architectural
and
structural
integrity
of
the
building.
Effects
on
the
historically
significant
Roundhouse
building
DSP,
DSP-V,
CPP,
&
CPP-V
scenarios
4.D-1b:
All
Project
Site
development
within
50
feet
of
the
Roundhouse
or
the
Machinery
&
Equipment
building
be
designed
to
ensure
their
architectural
compatibility
with
the
historic
Roundhouse,
and
to
ensure
that
new
buildings
do
not
overwhelm
or
unnecessarily
contrast
with
these
historic
buildings.
To
this
end,
all
development
projects
shall
incorporate
a
minimum
50-foot
structural
setback
and
appropriate
heights,
volumes,
and
materials
for
any
proposed
new
buildings
in
the
immediate
vicinity
to
ensure
compatibility
with
the
Roundhouse
and
the
Machinery
&
Equipment
building.
Appropriate
heights
of
new
construction
adjacent
to
the
Roundhouse
would
be
the
same
as
(about
25
feet),
or
slightly
greater
than
(i.e.,
up
to
15
feet
greater
than),
the
existing
height
of
the
building.
Appropriate
heights
of
new
construction
adjacent
to
the
Machinery
&
Equipment
building
would
be
the
same
as
(about
40
feet)
or
slightly
greater
than
(up
to
10
feet
greater
than),
the
existing
height
of
the
building.
Appropriate
materials
for
new
construction
in
the
immediate
vicinity
of
either
building
would
be
brick
cladding
and/or
cementitious
materials
painted
a
similar
dark
red
color,
as
well
as
Spanish
tile
roof
cladding.
Appropriate
volumes
for
new
development
that
would
face
the
Roundhouse
should
mirror
the
curve
of
the
existing
structure.
Appropriate
volumes
for
new
development
in
the
vicinity
of
the
Machinery
&
Equipment
building
would
be
rectilinear
in
massing.
All
development
projects
within
50
feet
of
the
Roundhouse
or
the
Machinery
&
Equipment
building
shall
be
subject
to
City
design
permit
review
and
approval
prior
to
development.
Site-specific
developer(s)
of
properties
within
50
feet
of
the
Roundhouse
and
the
Machinery
&
Equipment
buildings
City
of
Brisbane
approval
authority
for
site-specific
development
within
50
feet
of
the
Roundhouse
and
the
Machinery
&
Equipment
buildings
The
Community
Development
Director
shall
review
proposed
site-
specific
development
plans
for
compliance
with
Mitigation
Measure
4.D-1b
prior
to
staff
approval
for
development
not
subject
to
public
hearings
and
before
submittal
to
the
Planning
Commission
for
development
projects
requiring
public
hearings.
Approval
of
site-specific
development
within
50
feet
of
the
Roundhouse
and
the
Machinery
&
Equipment
buildings
in
compliance
with
Mitigation
Measure
4.D-1b.
Mitigation
Measure
Responsibility
for
Implementation
Enforcement
Responsibility
Monitoring
Responsibility/
Frequency
Actions
Indicating
Compliance
Brisbane
Baylands
Final
EIR
4-41
May
2015
Previous Next