4.
Mitigation
Monitoring
and
Reporting
Program
Mitigation
Monitoring
and
Reporting
Matrix
(continued)
Significant
Impact
Being
Mitigated
Biological
Resources
(cont.)
Planning
Department
for
review
and
approval
prior
to
construction.
The
City
of
Brisbane
Planning
Department
shall
ensure
that
lighting-related
measures
to
reduce
the
risk
of
bird
collisions
have
been
incorporated
into
the
design
of
such
buildings
to
the
extent
practicable.
Restrictions
on
the
movement
of
wildlife
species
DSP,
DSP-V,
CPP,
&
CPP-V
scenarios
4.C-4e:
During
design
of
any
building
greater
than
100
feet
tall,
the
applicant
and
architect
shall
consult
with
a
qualified
biologist
experienced
with
urban
building
bird
strikes
design
issues
(as
approved
by
the
City
of
Brisbane
Planning
Department)
to
identify
measures
related
to
the
external
appearance
of
the
building
to
minimize
the
risk
of
bird
strikes.
Such
measures,
which
may
include
the
following
and/or
other
measures,
shall
reflect
most
current
practice
in
in
bird
strike
protection,
and
be
incorporated
into
the
building’s
design:
Treat
all
windows
to
decrease
reflectivity,
including
use
of
non-reflective
tinted
glass.
Use
window
films
to
make
windows
visible
to
birds
from
the
outside.
Use
of
outdoor
lighting
and
colors
of
lighting
that
increase
visibility
of
buildings
to
birds
without
substantially
increasing
energy
consumption
or
decreasing
public
safety.
Use
external
surfaces/designs
that
break
up
reflective
surfaces.
Place
bird
attractants,
such
as
bird
feeders
and
baths,
at
least
three
feet
and
preferably
30
feet
or
more
from
windows
in
order
to
reduce
collision
mortality.
A
report
of
the
design
measures
considered
and
adopted
shall
be
provided
to
the
City
of
Brisbane
Planning
Department
for
review
and
approval
prior
to
construction.
The
City
of
Brisbane
Planning
Department
shall
ensure
that
building
design
related
measures
to
reduce
the
risk
of
bird
collisions
have
been
incorporated
to
the
extent
practicable.
Applicants
for
development
of
buildings
greater
than
100
feet
in
height
City
of
Brisbane
Building
Official
The
City
Building
Official
shall
review
the
proposed
design
of
any
building
proposed
to
be
100
feet
in
height
or
greater,
and
shall
issue
building
permits
only
for
those
buildings
determined
to
be
in
compliance
with
Mitigation
Measure
4.C-4e.
Issuance
of
building
permits
for
building
100
feet
in
height
or
greater
in
compliance
with
Mitigation
Measure
4.C-4e.
Mitigation
Measure
Responsibility
for
Implementation
Enforcement
Responsibility
Monitoring
Responsibility/
Frequency
Actions
Indicating
Compliance
Brisbane
Baylands
Final
EIR
4-37
May
2015