3.
Revisions
to
the
Text
of
the
Draft
EIR
TABLE
5.8
(Continued)
COMPARISON
OF
IMPACTS
FOR
PROJECT
SITE
SCENARIOS
AND
ALTERNATIVES
Proposed
Project
Site
Development
Scenario
Impacts
DSP
SM
DSP-V
SM
CPP
SM
CPP-V
SM
No
Project–General
No
Project–No
Build
Plan
Buildout
Impact:
Because
no
development
would
occur,
no
impacts
related
to
increased
demand
for
fire
services
would
result.
Impact:
Because
existing
NCFA
facilities
and
staffing
do
not
meet
current
response
goals,
increased
demand
will
require
a
new
fire
station
or
expansion
of
the
existing
station(s)
to
provide
adequate
fire
protection
service
to
the
Project
site.
Although
this
alternative
would
result
in
a
smaller
onsite
population
than
the
reduced
intensity
alternatives
and
considerably
smaller
than
the
scenarios,
a
significant
impacts
on
fire
protection
services
would
result,
and
expansion
of
existing
facilities
would
be
required.
As
with
all
proposed
development,
preparation
of
a
Fire
Protection
Services
Plan
would
be
required
to
determine
the
needed
timing
for
new
facilities,
equipment,
and
staffing.
Alternatives
Renewable
Energy
Generation
Impact:
Because
existing
NCFA
facilities
and
staffing
do
not
meet
current
response
goals,
increased
demand
will
require
a
new
fire
station
or
expansion
of
the
existing
station(s)
to
provide
adequate
fire
protection
service
to
the
Project
site.
Although
this
alternative
would
result
in
a
smaller
onsite
population
than
other
alternatives
involving
building
construction,
alternatives
and
considerably
smaller
than
the
scenarios,
a
significant
impacts
on
fire
protection
services
would
result,
and
expansion
of
existing
facilities
would
be
required.
As
with
all
proposed
development,
preparation
of
a
Fire
Protection
Services
Plan
would
be
required
to
determine
the
needed
timing
for
new
facilities,
equipment,
and
staffing.
Reduced
Intensity
Non-Residential
Impact:
Because
existing
NCFA
facilities
and
staffing
do
not
meet
current
response
goals,
increased
demand
will
require
a
new
fire
station
or
expansion
of
the
existing
station(s)
to
provide
adequate
fire
protection
service
to
the
Project
site.
Although
this
alternative
would
result
in
considerably
smaller
onsite
population
than
the
scenarios,
a
significant
impact
on
fire
protection
services
would
result,
and
expansion
of
existing
facilities
would
be
required.
As
with
all
proposed
development,
preparation
of
a
Fire
Protection
Services
Plan
would
be
required
to
determine
the
needed
timing
for
new
facilities,
equipment,
and
staffing.
Reduced
Intensity
Mixed
Use
Impact:
Because
existing
NCFA
facilities
and
staffing
do
not
meet
current
response
goals,
increased
demand
will
require
a
new
fire
station
or
expansion
of
the
existing
station(s)
to
provide
adequate
fire
protection
service
to
the
Project
site.
Although
this
alternative
would
result
in
considerably
smaller
onsite
population
than
the
scenarios
(but
larger
than
other
alternatives),
a
significant
impact
on
fire
protection
services
would
result,
and
expansion
of
existing
facilities
would
be
required.
As
with
all
proposed
development,
preparation
of
a
Fire
Protection
Services
Plan
would
be
required
to
determine
the
needed
timing
for
new
facilities,
equipment,
and
staffing.
Project
Site
development
under
the
DSP
or
DSP-
V
scenario
is
expected
to
more
than
double
current
fire
service
demands
within
the
City,
while
development
of
the
CPP
or
CPP-V
scenario
will
nearly
double
fire
service
demands
within
the
City.
Because
existing
NCFA
facilities
and
staffing
Impact
4.L-2:
Would
do
not
meet
current
response
goals,
increased
demand
will
require
a
new
fire
station
or
the
Project
result
in
expansion
of
the
existing
station(s)
to
provide
substantial
adverse
adequate
fire
protection
service
to
the
Project
physical
impacts
site.
associated
with
the
provision
of
new
or
physically
altered
fire
To
ensure
adequate
fire
protection
services
and
facilities
for
the
Project
site
while
maintaining
protection
or
emergency
response
adequate
response
times
throughout
the
City,
specific
plan(s)
for
development
within
the
Project
facilities,
need
for
Site
will
be
required
as
part
of
the
planning
review
new
or
physically
altered
fire
protection
process
to
prepare
and
implement
a
Fire
Protection
Services
Plan
that
provides
for
the
or
emergency
timely
provision
of
fire
protection
facilities,
response
facilities,
equipment,
and
staffing.
The
Fire
Protection
the
construction
of
Services
Plan
will
specify
the
means
and
which
could
cause
methods
that
will
be
employed,
over
time,
to
significantly
ensure
that
the
fire
service
performance
environmental
standards
are
met.
Implementation
of
mitigation
impacts,
in
order
to
maintain
acceptable
would
reduce
impacts
to
less
than
significant
for
all
scenarios.
staffing
ratios,
response
times
or
other
performance
objectives?
Impacts:
SU
–
Significant
Unavoidable
Impact
No
Impact
Brisbane
Baylands
Final
EIR
SM
–
Significant,
but
Mitigable
Impact
N/A
–
Not
Applicable
LTS
–
Less
than
Significant
Impact
3-189
May
2015
Previous Next