CPA2
METHODOLOGY
AND
ASSUMPTION
DEFICIENCIES
38
did
not
allow
the
Project
to
be
modeled
as
a
complete
system
but
rather
required
the
model
to
be
analyzed
in
separate
pieces.
Due
to
t
he
chaotic
nature
of
wind
and
scope
of
the
Project
,
it
is
practically
impossible
to
accurately
represent
the
multitude
of
factors
that
include
channeling
wind
at
different
primary
directions
within
the
area
mod-
eled
due
to
complex
topography,
micro-systems
of
persistent
vortices,
eddies,
and
wind
shadows,
variance
according
to
temperature
and
source
of
the
wind
(high
pressure
gradient
or
thermal
gradient),
the
impact
of
substantial
wind
swell
on
turbulence
[15],
the
impact
of
local
thermal
variation
caused
by
development
(e.g.
"heat
bubbles"
due
to
large
areas
of
paved
surface),
thermal
induced
convection
cells
resulting
in
upwelling
and
turbulent
eddies,
the
different
characteristics
of
the
upwind
topography
and
the
CP
SRA
during
higher
and
lower
wind
conditions,
and
others.
In
discussions
with
ESA,
it
was
revealed
that
what
was
modeled
was
supposed
to
be
the
''worst
case"
in
terms
of
impact
to
the
CP
SRA.
It
is
hard
to
know
a
priori
what
constitutes
worst
case,
especially
when
t
he
criteria
for
acceptable
use
of
the
Resource
is
not
even
defined.
There
are
at
least
two
variables
of
interest
including
reduction
in
mean
wind
speed
and
increase
in
wind
turbulence
intensity.
The
relationship
between
these
two
variables
is
complex.
One
can
imagine
approximating
the
Project
with
a
single
large
wall
the
height
of
which
represents
t
he
maximum
possible
building
height
for
the
entire
Project.
Presumably
this
would
result
in
maximum
wind
speed
reduction
impact.
Alternatively,
one
can
imagine
modeling
the
Project
with
a
series
of
buildings
of
varying
heights
and
gaps
to
try
to
achieve
the
maximum
surface
roughness.
P
resumably
this
would
result
in
the
maximum
wind
turbulence
intensity
increase
impact
but
not
necessarily
the
largest
possible
wind
speed
reduction.
In
absence
of
t
he
actual
site
plan
and
building
details,
it
is
unclear
how
one
can
evaluate
t
he
''worst
case"
impacts
with
only
a
single
model
that
would
simultaneously
maximize
both
of
these
impact
variables.
Modeling
an
Undefined
Project
with
Certainty
As
Project
site
plan
and
programming
details
are
not
yet
defined,
it
is
unknown
how
the
Project
could
be
faithfully
modeled
without
a
thorough
examination
of
alternatives,
which
was
not
reported.
The
DEIR
presents
impact
results
as
if
they
are
the
only
possible
outcome.
In
reality,
the
results
are
highly
dependent
on
t
he
finished
base
elevation,
actual
placement
and
configuration
of
buildings,
heights,
orientations,
clusterings,
density,
massings,
regularity,
streamlining,
on-site
and
off-site
topography,
open
space,
landscaping,
impervious
surface,
surrounding
development
such
as
inclusion
of
t
he
Executive
Park
buildout
and
proposed
Recology
expansion,
and
other
factors
that
are
not
known
at
t
his
time.
5-409