BSD
John
Swiecki
City
of
Brisbane
2
October
2013
Page
2
This
was
a
very
fruitful
meeting
and
we
gained
a
better
understanding
regarding
the
development
of
this
project
and
how
the
District's
facilities
may
be
impacted.
The
DEIR
states
that
certain
District
sewer
lines
serving
existing
customers
along
Tunnel
Avenue
and
Industrial
Way
would
be
replaced
and
constructed
to
District
standards.
However.
no
mention
was
made
regarding
the
use
of
the
District's
Carlyle
Pump
Station
(PS)
and
associated
force
main.
t
~ont.
At
this
meeting
UPC
indicated
that
the
initial
developments
would
occur
at
the
intersection
of
Geneva
Avenue
and
Bayshore
Boulevard
and
that
UPC
would
like
to
deliver
wastewater
to
the
Carlyle
PS
to
be
pumped
to
San
Francisco.
Currently
all
discharges
along
Bayshore
Boulevard
and
Industrial
Way
are
pumped
to
San
Francisco
while
all
discharges
along
Tunnel
Avenue
flow
by
gravity
to
San
Francisco.
The
Carlyle
PS
contains
4
pumps.
During
dry
weather
periods
only
one
pump
operates
at
a
time.
However,
during
wet
weather
periods
multiple
pumps
operate.
It
is
not
uncommon
to
have
2
pumps
operating.
One
rare
occasions
3
or
4
pumps
will
operate,
but
only
for
short
periods
of
time.
To
increase
the
capacity
of
the
Carlyle
PS
it
will
be
necessary
to
either
install
larger
pumps
that
operate
at
a
higher
head
(pressure)
or
construct
a
larger
parallel
force
main
to
reduce
the
total
pumping
head.
The
District
is
reluctant
to
pursue
the
first
option
as
that
would
increase
the
operating
pressure
on
the
43-year
old
asbestos
cement
(AC)
force
main.
The
District
has
recently
evaluated
the
second
option.
The
District
beheves
that
with
careful
early
planning
there
would
be
a
less
than
significant
impact
to
District
facilities
provided
certain
conditions
are
met.
These
include:
•
•
•
The
District
is
i11clude<..i
eariy
in
aii
planning
activities
and
is
consulted
as
projsct&
are
developed
All
District
wastewater
collection
lines
replaced
are
replaced
to
District
Standards
which
may
need
to
be
revised
due
to
the
unique
soil
conditions
at
the
site
A
requirement
that
the
Developer
grants
the
District
an
easement
in
a
public
right-of-way
for
a
parallel
force
main
and
the
Developer
construct
at
its
expense
a
parallel
force
main
and
any
associated
improvements
at
the
Carlyle
Pump
Station
at
the
same
time
as
the
roadways
and
prior
to
any
paving.
The
developer
will
receive
credit
against
the
developer's
capacity
charge
obligations
based
on
the
value
of
construction
in
an
amount
to
be
determined
by
the
District.
The
District
ordinance
must
be
adhered
to,
especially
with
regard
to
connection
(entitlement)
fees.
3
4
•
5-40