3.
Revisions
to
the
Text
of
the
Draft
EIR
Ratliff
(1985).
The
basic
methodology
for
baseline
vegetation
survey
and
subsequent
mitigation
monitoring
will
be
generally
accepted
quantitative
vegetation
sampling
methods
to
permit
statistical
comparison
of
vegetation
composition
over
time,
as
well
as
mapping
the
meadow
vegetation
in
the
Poopenaut
Valley.
The
SFPUC
will
retain
the
services
of
a
qualified
biologist
to
assist
in
shaping
the
releases
from
Hetch
Hetchy
Reservoir
in
consideration
of
baseline
and
future
meadow
vegetation
data.
If
a
significant
decline
in
the
extent
or
diversity
of
native
meadow
vegetation
occurs,
releases
will
be
modified
as
needed
to
achieve
the
mitigating
effect
of
sustaining
the
existing
meadow
communities.
The
SFPUC
will
manage
reservoir
releases
for
this
purpose
by
releasing
the
expected
available
volume
of
water
in
the
reservoir
in
a
pattern
that
provides
flows
of
a
magnitude
that
inundate
the
meadows
and
streamside
alluvial
deposits
for
as
long
as
possible.
For
example,
rather
than
making
releases
at
a
constant
rate
each
day
(e.g.,
releasing
1,000
cubic
feet
per
second
for
seven
days),
the
SFPUC
could
release
the
same
volume
of
water
but
with
varying
cubic
feet
per
second
rates,
creating
flow
pulses
to
meet
the
objective.
As
part
of
this
measure
the
SFPUC
will
gather
baseline
data
regarding
the
extent,
species
composition
and
condition
of
the
existing
meadow
vegetation
within
the
Poopenaut
Valley.
Some
of
these
environmental
baseline
data
may
be
available
as
a
result
of
current
study
efforts
in
the
Poopenaut
Valley.
As
needed,
the
SFPUC
will
augment
this
information
by
carrying
out
vegetation
composition
surveys
in
the
meadow
before
implementing
the
WSIP
and
at
5
year
intervals
after
WSIP
implementation
to
assess
the
efficacy
of
mitigation
releases
in
maintaining
or
improving
the
percentage
cover
of
meadow
species
as
described
by
Ratliff
(1985).
Page
4.O-49
[See
page
for
the
original
comment]
REVISED
the
second
paragraph
as
follows:
Air
quality
impacts
of
the
onsite
recycled
water
plant
are
included
in
the
air
quality
impacts
evaluated
in
Section
4.B,
Air
Quality
.
While
the
recycled
water
plant
would
be
required
to
meet
Bay
Area
Air
Quality
District
(BAAQMD)
emissions
standards
and
therefore
be
considered
to
have
less-
than-significant
air
quality
impacts,
the
plant
would
contribute
to
the
significant
unavoidable
air
quality
impacts
identified
in
that
section.
To
address
odor
impacts,
Mitigation
Measure
4.B-8
requires
implementation
of
an
odor
management
plan
at
the
proposed
recycled
water
plant
with
sufficient
control
measures
to
meet
BAAQMD
odor
detection
thresholds.
At
a
minimum,
the
following
requirements
would
be
included
in
the
design
of
the
recycled
water
plant:
Odor
control
using
activated
carbon
canister
shall
be
provided
for
all
air
that
is
vented
from
lift
stations.
Brisbane
Baylands
Final
EIR
3-138
May
2015