3.
Revisions
to
the
Text
of
the
Draft
EIR
Bayshore
Industrial
Park
The
Bayshore
Industrial
Park
consists
of
a
series
of
metal
building
used
for
various
industrial
and
service
commercial
purposes,
such
as
warehousing/storage
and
auto
repair.
Based
on
the
age
of
these
buildings,
there
is
a
potential
for
the
presence
of
asbestos
and
lead-based
paint,
as
well
as
the
potential
for
ground
contamination
undetected
as
part
of
previous
studies
within
The
existing
industrial
park
is
planned
for
demolition
to
make
way
for
new
planned
uses
under
each
of
the
four
development
scenarios.
Such
demolition
could
result
in
the
introduction
of
asbestos
and
lead-based
paint,
as
well
as
potential
other
contaminants
in
the
soils
into
the
environment.
Conclusion:
To
avoid
significant
health
hazards
associated
the
Bayshore
Industrial
Park,
implementation
of
Mitigation
Measure
4.G-2j
will
be
required.
Mitigation
Measure
4.G-2j:
Prior
to
approval
of
any
demolition
plan
within
the
Bayshore
Industrial
Park,
any
building(s)
proposed
for
demolition
shall
be
tested
for
asbestos
and
lead-based
paint.
Should
asbestos
or
lead-based
paint
be
identified,
the
affected
building(s)
shall
be
remediated
to
the
satisfaction
of
the
RWQCB
pursuant
to
the
most
current
regulatory
standards
in
effect
at
the
time
of
remediation.
Prior
to
site
development
within
the
Bayshore
Industrial
Park,
soils
shall
be
tested
for
likely
constituents
of
concern
based
on
the
site’s
use
pursuant
to
the
requirements
of
the
RWQCB.
Human
health
risk
assessment(s)
for
sites
proposed
for
demolition
shall
be
prepared
based
on
the
future
uses
of
the
area
approved
by
the
City
of
Brisbane.
Should
risks
to
human
health
be
identified,
remediation
to
the
risk-based
remediation
standards
set
by
the
RWQCB
shall
be
completed
prior
to
initiating
grading
or
other
onsite
development.
Conclusion
with
Mitigation:
With
implementation
of
Mitigation
Measure
4.G-2j
,
hazards
from
potential
contamination
within
the
Bayshore
Industrial
Park
would
be
reduced
to
less
than
significant.
Page
4.G-101
[See
page
for
the
original
comment]
REVISE
the
first
paragraph
to
read
as
follows:
The
Project
Site
is
located
more
than
2
miles
from
the
nearest
public
airport,
the
San
Francisco
International
Airport,
or
airstrip,
and
is
not
located
within
the
65
dB
noise
contour
of
the
airport
an
airport
land
use
plan.
The
Project
Site
is
within
Airport
Influence
Area
A
–
Real
Estate
Disclosure
Area,
and
person(s)
offering
real
property
for
lease
or
sale
are
required
to
provide
an
airport
disclosure
statement.
Development
under
any
of
the
proposed
scenarios
would
not
conflict
with
an
airport
land
use
plan
nor
present
any
other
impact
related
to
a
public
airport
use
or
private
airstrip.
Brisbane
Baylands
Final
EIR
3-90
May